info@xboct.ca | (647) 401-7444 | 24/7 Licensed Electrical Contractor serving the GTA.

How Much Power Does an EV Charger Use?

A Level 2 home EV charger draws between 5.8 kW and 19.2 kW while it’s running, with most Canadian installations sitting at 7.7 kW or 11.5 kW. Over a month, charging one EV at home adds roughly 280 to 440 kWh to your bill — about the same as running a second fridge, a hot tub and an electric dryer combined.

Those are two different numbers and they answer two different questions. Draw is how much power the charger pulls at any given moment, which decides whether your electrical panel can handle it. Consumption is how many kilowatt-hours it burns over time, which decides what you pay. Here’s both, in Canadian units and Ontario rates.

How much power an EV charger draws

Power is voltage multiplied by current. A charger on a 240-volt circuit pulling 32 amps draws 7,680 watts, or 7.68 kW.

That number is a rate, not a quantity. You’ll see the phrase “7,200 watts per hour” repeated across the internet — it’s a unit error. A watt already is energy per unit of time. A 7.2 kW charger running for one hour consumes 7.2 kilowatt-hours.

Charger setting

Required breaker

Power drawn

Level 1 — 12 A at 120 V

Standard outlet

1.4 kW

16 A at 240 V

20 A

3.8 kW

24 A at 240 V

30 A

5.8 kW

32 A at 240 V

40 A

7.7 kW

40 A at 240 V

50 A

9.6 kW

48 A at 240 V

60 A

11.5 kW

80 A at 240 V

100 A

19.2 kW

The breaker column follows from the Canadian Electrical Code: EV charging is a continuous load, so a circuit may be loaded to no more than 80% of its rating. A 40-amp charger needs a 50-amp breaker. There is no way around this, and it’s the single most common reason a self-installed charger fails inspection.

Public DC fast chargers are a different category entirely, running from 50 kW to 350 kW. They’re commercial equipment on commercial service and aren’t relevant to a house — we cover why in our article on the fastest EV chargers.

Two things cap the draw below the table. Your vehicle’s onboard charger sets its own ceiling — most EVs won’t accept more than 11.5 kW on AC regardless of what the wall unit can supply. And most chargers are field-adjustable, so an 11.5 kW unit can be set to 7.7 kW to fit the circuit your panel can actually support.

How much electricity an EV charger uses in a month

This depends on how far you drive and how efficient your car is, not on which charger you installed. A 7.7 kW charger and an 11.5 kW charger delivering the same 300 kWh into the same battery consume nearly the same electricity — one just finishes sooner.

Natural Resources Canada rates every EV sold here in kilowatt-hours per 100 kilometres and bases its annual cost estimates on 20,000 km of driving per year. Current EVs land between roughly 14 and 23 kWh/100 km depending on size.

There’s also a conversion loss. Your car’s onboard charger turns AC into DC, and peer-reviewed testing puts overall Level 2 charging efficiency at about 85–90%. Level 1 is worse — closer to 84% — because the fixed overhead is a bigger share of a small trickle. That means the meter reads about 10–15% higher than what lands in the battery.

At 20,000 km per year, drawn from the wall:

Vehicle efficiency

Example

Per month

Per year

15 kWh/100 km

Efficient sedan

~285 kWh

~3,400 kWh

18 kWh/100 km

Mid-size crossover

~340 kWh

~4,100 kWh

20 kWh/100 km

Larger SUV

~380 kWh

~4,550 kWh

23 kWh/100 km

Electric pickup

~435 kWh

~5,200 kWh

Ontario winters push these numbers up. Cabin heating, battery warming and reduced charging efficiency below freezing mean January consumption commonly runs well above the annual average. Budget for the winter figure, not the yearly one.

What that costs on a Toronto Hydro bill

Natural Resources Canada uses $0.18/kWh as its all-in benchmark for electricity when calculating annual running costs. At that rate, the mid-size example above — about 4,100 kWh a year — costs roughly $735 per year, or about $61 a month.

You can do considerably better than that in Ontario, because the rate plan matters more than anything about the charger.

The Ontario Energy Board’s Ultra-Low Overnight plan prices electricity at 3.9¢/kWh between 11 p.m. and 7 a.m., every day of the week. That’s the electricity line of your bill; delivery and regulatory charges are billed separately and add several cents per kilowatt-hour on top. But the commodity portion is where the spread lives — ULO’s overnight rate is less than half the standard Time-of-Use off-peak price of 9.8¢, and a tenth of ULO’s own weekday on-peak rate of 39.1¢.

The practical consequence: schedule the charger to run inside the 11 p.m.–7 a.m. window and never outside it. Every Level 2 charger sold today has a built-in timer or app schedule, and most EVs can enforce a departure time from the car itself. A homeowner charging on ULO overnight and a homeowner charging on ULO at 5 p.m. are paying ten times different prices for identical electricity.

Rates are reset by the OEB once a year on November 1, so confirm the current figures before building a budget around them.

How much of your electrical service does a charger take?

This is the question that decides whether your EV charger installation is straightforward or expensive.

A 100-amp service supports about 24 kW across the entire house. A 200-amp service supports about 48 kW. Against that, an 11.5 kW charger on a 60-amp circuit is claiming 60 of your 100 available amps, or 60 of 200.

That’s not how the calculation actually works — a licensed electrician performs a load calculation that weighs your existing heating, range, dryer, air conditioning and water heater against the service rating, rather than simply adding up breaker sizes. But the scale is real, and in older Scarborough and East York homes still running 100-amp panels, the charger is usually the largest single load in the building.

Where capacity is tight, the code offers a cheaper answer than a bigger service. An electric vehicle energy management system monitors the home’s real-time demand and reduces or pauses charging when the house is drawing heavily. Under Rule 8-500 of the Canadian Electrical Code, that lets the charger be reduced or excluded in the load calculation — which often means a full-speed charger goes onto a 100-amp service without a service upgrade at all. Where it doesn’t, a panel upgrade is the alternative.

Can you use a 40-amp breaker for an EV charger?

Yes, on a properly sized circuit. A 40-amp breaker supports a charger set to 32 amps continuous, delivering 7.7 kW. This is a common and perfectly sensible residential configuration.

What you cannot do is put a 40-amp charger on a 40-amp breaker. That violates the 80% continuous-load rule and will fail inspection. A 40-amp charger requires a 50-amp breaker.

Is 30 amps enough for an EV charger?

For most drivers, yes. A 30-amp breaker supports 24 amps continuous, or about 5.8 kW. Over an eight-hour overnight window that’s roughly 46 kWh drawn — well above the 11 kWh or so a typical Canadian driver uses in a day at 20,000 km per year.

A 30-amp circuit becomes limiting if you drive substantially more than average, charge two vehicles, or run an inefficient large vehicle in winter. For a single commuter car it’s more than sufficient, and it’s often the practical answer in a home with limited panel capacity.

Three things that change the number

Does leaving the charger plugged in cost money?

A little, and not enough to act on. A Level 2 unit sitting idle draws a few watts to keep its electronics, safety circuits and Wi-Fi radio alive — typically low single digits, up to roughly 10 watts for a connected smart charger. Even at 10 watts continuously that’s about 88 kWh a year, which is a few dollars. Unplugging the cable from the car makes no difference at all; the draw belongs to the wall unit, which is hardwired.

Does charging to 100% every night use more electricity?

Yes, twice over. You’re putting more energy in, and the last stretch is less efficient — charging losses in the 80–100% window have been measured at roughly double those in the 20–80% range, because the battery accepts power more slowly and more of the input becomes heat.

Unless you need the full range the next morning, setting a daily charge limit of 80% uses less electricity per kilometre driven. Check your vehicle’s manual, since manufacturers of LFP-battery models often recommend periodic full charges for calibration.

Does a bigger charger use more electricity?

No. A charger is not an appliance that consumes energy on its own — it’s a controlled gate between your panel and your car’s battery. A 19.2 kW unit and a 7.7 kW unit putting the same 40 kWh into the same battery draw close to the same total from the meter. The larger one simply does it in a fifth of the time, and marginally more efficiently, because onboard chargers run closest to their rated efficiency near full power.

What a bigger charger changes is your peak demand, not your consumption — which is a panel-capacity question, not a billing one, for residential customers in Ontario.

Sizing this for your own home

Three inputs decide it: your vehicle’s maximum AC rate, your daily driving distance, and what your electrical panel can carry. The first two you know. The third requires a load calculation on your actual service, which in Ontario must be done by a Licensed Electrical Contractor who files a notification of work with the Electrical Safety Authority before the installation starts.

If you’re working out what your panel can support, our EV charger installation page covers scope, pricing and the permit process for Toronto and the GTA.

SOURCES / REFERENCES